PART 1 – GENERAL
- Products included: extruded polyvinyl chloride (PVC) windows of the following types:
- Horizontal Sliding
- Vertical Sliding (Single-hung)
- Casement
- Fixed (Picture)
- Sliding Patio Door
- Submittals
- Product cross-section drawings, as needed.
- U-factor chart(s).
- Structural ratings based on AAMA/WDMA 101/I.S.2
- Shop drawings including/or window schedule, window elevations, sections and details.
- Weathervane will provide test reports when tested product configurations match configurations specified for a particular project. At the option of the buyer, Weathervane will arrange for testing by an accredited laboratory for the purpose of providing test report(s) for project-specific product configurations and sizes.
- Delivery, Storage, and Handling
- Follow manufacturer’s label instructions
- Warranty
- Warranty shall cover defects in material and workmanship
- Warranty shall provide repair or replacement parts and labor.
- Weathervane’s Limited Lifetime Warranty (submitted separately) shall apply without modification. No other warranties or special warranty provisions shall apply to Weathervane products other than as provided in the Weathervane Warranty.
PART 2—PRODUCTS
- Manufacturer: Weathervane Windows LLC
7911 S. 188th St.
Kent, WA 98032
(425) 282-0777
- Window Series: Vantage I
- Door Series: VX
- Materials
- Vinyl (PVC): Integral color PVC compound containing impact-resistant solid plasticizer, titanium dioxide UV inhibitor, and surface and color stabilizers.
- Comply with ASTM D4218 and AAMA 101
- General Performance Requirements
- Thermal performance: Comply with and certify under NFRC 100
- Air Infiltration, Water Infiltration, and Structural Loading: Comply with AAMA 101.
- Forced-Entry Resistance: Comply with CAWM 310-90.
- Window Types
- Horizontal Slider XO or OX—Vantage I Series
- Frame: 3.375 inch depth with 1.375 inch nailing fin set-back from exterior
- Reinforcement: Steel reinforced fixed meeting rail
- Hardware:
- Solid brass, adjustable sash rollers
- Cam lock or positive action (self-latching) lock
- Screened, operable air vent option (trickle ventilator)
- Weatherstrip: Polypropylene pile with fin seal
- Performance: for units up to 30 sq. ft. rough opening area
- ASTM E283-04 Air Infiltration at 1.57 psf test pressure
Less than 0.30 cfm/sq.ft.
- ASTM E330-02 Uniform Load
No damage or permanent set at 37.5 psf (pos/neg)
- ASTM E547-00 Water Penetration
No leakage at 3.75 psf
- Horizontal Slider XOX—Vantage I Series
- Frame: 3.375 inch depth with 1.375 inch nailing fin set-back from exterior
- Reinforcement: Steel reinforced fixed meeting rails
- Hardware:
- Solid brass, adjustable sash rollers
- Cam lock or positive action (self-latching) lock
- Screened, operable air vent option (trickle ventilator)
- Weatherstrip: Polypropylene pile with fin seal
- Performance: for units up to 45 sq. ft. rough opening area
- ASTM E283-04 Air Infiltration at 1.57 psf test pressure
Less than 0.30 cfm/sq.ft.
- ASTM E330-02 Uniform Load
No damage or permanent set at 30 psf (pos/neg)
- ASTM E547-00 Water Penetration
No leakage at 3.75 psf
- Single-hung—O/X Vantage I Series
- Frame: 3.375 inch depth with 1.375 inch nailing fin set-back from exterior.
- Reinforcement: Steel reinforced fixed meeting rail.
- Hardware:
- Steel spring block and tackle sash balances.
- Cam lock or positive action (self-latching) lock.
- Screened, operable air vent option (trickle ventilator)
- Weatherstrip: Polypropylene pile with fin seal
- Performance: for units up to 28 sq. ft. rough opening area
- ASTM E283-04 Air Infiltration at 1.57 psf test pressure
Less than 0.30 cfm/sq.ft.
- ASTM E330-02 Uniform Load
No damage or permanent set at 37.5 psf (pos/neg)
- ASTM E547-00 Water Penetration
No leakage at 4.5 psf
- Casement
- Frame: 3.375 inch depth with 1.375 inch nailing fin set-back from exterior
- Reinforcement: Aluminum reinforced hinges and roto operator
- Hardware:
- Steel 2-bar leaf hinges and roto operator.
- Multipoint locks, 1 to 4 locking points
- Screened, operable air vent option (trickle ventilator)
- Weatherstrip: two rows, compressible, foam-filled bulb seal
- Performance: for units up to 16.5 sq. ft. rough opening area
- ASTM E283-04 Air Infiltration at 1.57 psf test pressure
Less than 0.30 cfm/sq.ft.
- ASTM E330-02 Uniform Load
No damage or permanent set at 37.5 psf (pos/neg)
- ASTM E547-00 Water Penetration
No leakage at 6.0 psf
- Fixed—Vantage I Series
- Frame: 3.375 inch depth with 1.375 inch nailing fin set-back from exterior.
- Performance: for units up to 40 sq. ft. rough opening area
- ASTM E283-04 Air Infiltration at 1.57 psf test pressure
Less than 0.30 cfm/sq.ft.
- ASTM E330-02 Uniform Load
No damage or permanent set at 60 psf (pos/neg)
- ASTM E547-00 Water Penetration
No leakage at 6.0 psf
- Sliding Patio Door XO or OX—VX Series, Standard or French Rail
- Frame: 4.913 inch depth with 1.375 inch nailing fin set-back from exterior.
- Reinforcement: Steel reinforced fixed and operating panel interlocks and lock stile.
- Hardware:
- Dual adjustable steel rollers
- Single-point lock
- Die-case interior and exterior handles with powder-coated finish
- Screened, operable air vent option (trickle ventilator)
- Weatherstrip: Polypropylene pile with fin seal
- Performance: for units up to 55 sq. ft. rough opening area
- ASTM E283-04 Air Infiltration at 1.57 psf test pressure
Less than 0.30 cfm/sq.ft.
- ASTM E330-02 Uniform Load
No damage or permanent set at 37.5 psf (pos/neg)
- ASTM E547-00 Water Penetration
No leakage at 3.75 psf
- Glazing
- Exterior-glazed with removable glass stops
- Insulated glass units: Comply with ASTM E 774, Class A
- Thickness: 0.750 inch thickness, minimum, with 0.50 inch airspace
- Glazing type: PPG Solarban® 60 Low-e glass, insulated.
- Spacer bar: Super Spacer® or equivalent “warm edge” spacer
- U-factor: 0.30 or less with argon gas fill
0.35 or less with air fill
- Solar heat gain coefficient: 0.50 or less
- Insect Screens (except for fixed windows)
Provide painted aluminum screen frames with charcoal colored fiberglass mesh.
- Fabrication
- Frames and sash shall have welded corners, trimmed and finished.
- Provide internal steel or aluminum reinforcement according to Manufacturer’s standard.
- Factory glaze with snap-in PVC glazing stops applied to the exterior.
- Finish
- Frame, sash, and screen shall be Manufacturer’s standard White or Tan color, as specified on window schedule.
- Color match all components
PART 3—INSTALLATION
- Examine openings and verify installation dimensions
- Correct any unsatisfactory framing conditions
III. Install windows in accordance with Manufacturer’s label recommendations or equivalent practice
IV. Do not remove temporary NFRC label
V. Install insect screen
VI. Verify window frame drainage holes (weep holes), where present, are open and functioning.
VII. Field Quality Control
Weathervane will submit to field testing by an AAMA accredited testing agency. In lieu of AAMA accreditation, Weathervane reserves the right to challenge, and if necessary, to reject any test results produced by any entity shown to be unqualified. Field testing shall be according to AAMA 502-02 with static test pressures of two-thirds the prescribed test pressure required for the above listed DP ratings. In the event of test failure, Weathervane shall have to opportunity to repair or modify the failed window for retest. Upon acceptance after retest, Weathervane shall make the same repairs or modifications, as needed, to all windows of that type. However, Weathervane reserves the right to treat minor test failures caused by variations in workmanship as isolated occurrences that shall not require repairs to all windows if it is the judgment of Weathervane that such failures are random, are likely to occur only under test conditions, and in any event do not, if present, pose a threat to persons or property. Weathervane shall instead rely on the provisions of the Weathervane Limited Lifetime Warranty as the sole remedy in the event of such failures.
End of Section |